Item specifice

Output Power:
30-40kW
Inveter Efficiency:
98.8%
Output Voltage(V):
230V/400V
Input Voltage(V):
1100V
Output Current(A):
48.3A-64.3A
Output Frequency:
50HZ/60HZ

CNBM 30kW 33kW 36kW 40kW Three Phase On-Grid Solar Inverter PV Solution

XG30kW-40kW Three Phase On-Grid Solar Inverter



XG30KTR

XG33KTR

XG36KTR

XG40KTR

Input(DC)





Max. Input Power

48 kW

52.8 kW

57.6 kW

64 kW

Max. Input Voltage

1100V

Start Voltage

250V

Rated Input Voltage

600V

Full-load MPP Voltage Range

500V-800V

MPPT Voltage Range

200V-1000V

Number of MPP Trackers

3

4

String per MPPT

2

Max.Current per MPPT

26A

Max.Short Circuit Current per MPPT

32A

Output(AC)





Max. Output Current

48.3 A

53 A

57.8 A

64.3 A

Rated Output Power

30 kW

33 kW

36 kW

40 kW

Max. Output Power

33.3 kVA

36.6 kVA

39.6 kVA

44 kVA

Rated Grid Frequency

50 Hz / 60 Hz

Rated Grid Voltage

230Vac / 400Vac, 3L / N / PE

Power Factor

>0.99 (0.8 leading~0.8 lagging)

THDi

<3% (Rated Power)

Efficiency





Max. Efficiency

98.60%

European Efficiency

98.50%

MPPT Efficiency

99.90%

Protection





DC reverse polarity protection

Yes

Anti-Islanding protection

Yes

AC short circuit protection

Yes

Residual current monitoring unit

Yes

Insulation resistance monitoring

Yes

Ground fault monitoring

Yes

Grid monitoring

Yes

PV string monitoring

Yes

Surge protection

Type II

AFCI protection

Optional

Communication





Display

LED / LCD / WiFi+App

Communication

StandardRS485

OptionalWiFi / GPRS / Ethernet

Standard Compliance





Grid Connection Standards

IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4105:2018,

VDE-AR-N 4120:2018, EN 50549, AS/NZS 4777.2:2020, CEI 0-21, VDE0126-1-1/A1 VFR 2014,UTE C15-712-1:2013,

 DEWA DRRG, NRS 097-2-1, MEA/PEA, C10/11, G98/G99

Safety/EMC

IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011

General Data





Dimensions (W*H*D)

600 x 430 x 230 mm

Weight

30 kg

32 kg

Operating Temperature Range

-30° C ~ +60° C

Cooling Method

Smart Cooling

Protection Degree

IP66

Max. Operating Altitude

4000 m

Relative Humidity

0 ~ 100%

Topology

Transformerless

Night Power Consumption

< 1 W


 MARKETING & SERVICE NETWORK

CNBM global sales team provides customers with professional and efficient pre-sale,

in sale and after-sale services, and enhances the added value of the brand with high-quality services.

  

Products Details:           

High voltage protection            Over load protection   

Battery reverse connected protection    Dust-proof

Low voltage protection            Overheating protection

Output short-circuit protection           Insect prevention

 

Q:What is the difference between a PV grid-connected inverter and an off-grid inverter?
Grid-connected inverter does not need energy storage, but the energy can not be controlled, the number of photovoltaic sent to send online how much, simply do not want people to.
Q:Three-phase photovoltaic inverter grid, the use of phase-locked loop is what?
Photovoltaic inverters for grid-connected photovoltaic power generation systems are primarily capable of receiving DC power from photovoltaic arrays and converting them into sine-wave currents of the same frequency and in phase with the access grid for powering the grid or local loads.
Q:In a photovoltaic grid-connected project, the role of the inverter is to convert the voltage into AC 220V or 380V for the grid, since the transformer will raise the voltage again
Part of the distributed grid-connected projects, the basic are "spontaneous use, the power of the Internet," these do not need to boost, because the extra power is actually consumed by the surrounding electricity users, do not boost to a Level power grid;
Q:What is the difference between a grid-connected inverter and an off-grid inverter? What are the advantages of a hybrid inverter?
Grid-connected inverter will be directly sent to the power grid, so to track the frequency of the grid, phase, the equivalent of a current source. Of course, there are some inverters that have a low-pressure through the ability to do PQ adjustment.
Q:The function of photovoltaic grid - connected inverter
In general, single-phase h-bridge is a common configuration of dc / ac-level, but can also be used in three-phase and other configurations.
Q:Grid-connected inverter is generally divided into photovoltaic power generation grid-connected inverter, wind power grid-connected inverter, power equipment and grid-connected inverter and other power generation equipment power generation inverter.
The grid inverter is a current source, the output voltage is basically the grid voltage, may be slightly raised.
Q:What are the methods of photovoltaic grid-connected inverter control
Sine wave output inverter control integrated circuits, sine wave output of the inverter, the control circuit can be used microprocessor control, such as INTEL company produced 80C196MC, Motorola produced MP16 and MI-CROCHIP company PIC16C73 and so on, these single-chip microcomputer has a multi-channel PWM generator,
Q:Photovoltaic grid-connected inverter without DC emc how will happen
by means of energy converters can be converted into electrical energy. The process of converting light energy directly into electrical energy is precisely the response to photovoltaic effects. Without the need for any other mechanical parts, the energy in
Q:What is the difference between low voltage grid connection and medium voltage grid connection?
When the power grid failure or disturbance caused by the power supply and network voltage drop, in the voltage drop range, the power group can be uninterrupted through the inverter and network operation.
Q:Generally a large grid-connected photovoltaic power plant will have several inverters
, This method is simple to design, easy maintenance, but also for the power grid harmonics smaller, good power quality!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

- Self introduction

- Required specifications

- Inquire about price/MOQ

This is not what you are looking for? Post Buying Request

Hot Searches

Related keywords